Technical Parameters of Electric Actuator

  • Product Description

  • Product Model

  • Technical Parameters

  • Product Description:

  • Product Model:

  • Technical Parameters:

    HT-10BD Performance Parameter:

    Model HT-10BD
    Power Supply(V) DC24 AC24 AC110 AC220 AC380
    Output toque(Nm) 100
    Motion times(S) 10 30
    Scope of rotary anqle(°) 0~360
    Motor Power(W) 20 25
    Rated current(A) 0.85 3 0.7 0.32 0.2
    Machine Weight(KG) 4 43
    Insulation Resistance(MΩ) DC24V:100/250VDC AC110V/220V/380V:100/500VDC
    Voltage Resistance Rating DC24V:500VAC,AC110V/220V:1500VAC.AC380V:1800VAC(1Minute)
    Protection Level IP68
    Installation Position Rotary degree:360°
    Electriad connection Each one or M18x1.5 water-proof cable connectors、Electric Power Lines、Signal Lines
    Environment temperature -30℃~+60℃
    Circuit control B、S、K、R、A、D、H、T
    Optional function t Over torque protectors t Dehumidify heater


    HT-20/40/60BD Performance Paramenter:

    Model HT-20BD HT-40BD HT-60BD
    Power Supply(V) DC24 AC24 AC110 AC220 AC380 DC24 AC24 AC110 AC220 AC380 DC24 AC24 AC110 AC220 AC380
    OutPut toque(Nm) 200 400 600
    Motion times(S) 12 30/60 15 30/60 20 45/60
    Scope of ratary angle(°) 0~90 0~90 0~90
    Motor Power(W) 40 70 90 90
    Rated cument(A) 1.2 7.5 1.6 0.88 0.4 2.5 9 2.2 1 0.48 2.5 9 2.2 1 0.5
    Machine Weight(KG) 8.7 93 8.8 10 8.8 10
    Insulation Resistance(MΩ) DC24V:100/250VDC AC110V/220V/380V:100/500VDC
    Voltage Resistance Rating DC24V:500VAC,AC110V/220V:1500VAC.AC380V:1800VAC(1Minute)
    Protection Level IP68
    Installation Position Rotary degree:360°
    Electriad connection Each one or M18x1.5 water-proof cable connectors、Electric Power Lines、Signal Lines
    Environment temperature -30℃~+60℃
    Circuit control B、S、K、R、A、D、H、T
    Optional function t Over torque protectors t Dehumidify heater


    Power Supply:

    机型
    Mode
    熔断器
    Fuse
    电压
    Voltage
    AC380V AC220V AC110V AC24V DC24V
    HT-05BD 2A 2A 3A 5A 5A
    HT-10BD 2A 3A 5A 7A 7A
    HT-20/40/60BD 3A/5A 5A/7A 7A/10A 10A/11A 15A
    HT-100/200BD 5A 7A 10A 20A


    Note: 1. A parallel connection of the live wires of two or several electric actuators is not permitted. It is impossible to control several electric actuators by one point of junction only and otherwise it will result an out of control and electric actuator overheating.

         2. It is necessary to reserve the space for the inlet wire and manual operation. The annual operation is prohibited when the system is energized.

友情链接: